In article Brad
Knowles writes:
>At 5:21 PM -0800 2005-03-18, David Schwartz wrote:
>
>> A machine reports a time of X and it reports its own accuracy as Y and
>> the round trip time is Z. Why does this one machine not define an interval
>> X+Y+Z to X-Y-Z?
>
> Because we're talking about intervals between servers.
The intervals relevant for the clock selection algorithm are per server.
See e.g. "Clock select principles" on page 9 of the "NTP Architecture,
Protocol and Algorithms" document available at
http://www.eecis.udel.edu/~mills/ntp.html .
--Per Hedeland
per@hedeland.org |